Welcome to Hebi City Huanuo Electron Science and Technology Co.,Ltd.

Service Hotline

400 8392 001

Current location:Home >Element analyzer series > FL-900A microcomputer automatic fluorine and chlorine analyzer (double tube titration)
Sulfur Meter Series Calorimeter Series Industrial analyzer series Element analyzer series Coal Ash Fusibility Test Series Gas detection tube series Coke Testing Equipment Series Crushing Sampling Series
Product Name:FL-900A microcomputer automatic fluorine and chlorine analyzer (double tube titration)
Product price:
Shelf time:2022-02-16
  • Features
  • Range
  • Parameter
  • Adopt standard
  • Performance characteristics

    1. Double tube structure, can automatically decompose two samples at the same time, a single sample can produce two results of fluorine and chlorine, realize continuous measurement, no need to manually transfer samples

    2. The compressor refrigeration system is adopted, which can be recycled without water storage, effectively saving water consumption.

    3. Use Chinese LCD display, friendly interface and simple operation.

    4. Using PID to control the furnace flow, the temperature control accuracy is high, and the service life of the silicon carbon tube is effectively extended.

    5. The computer program automatically collects various curves and measurement data, and automatically calculates the measurement results.

    6. The temperature measurement uses high-precision, low-temperature drift components to ensure the long-term accuracy of temperature measurement.

    7. High degree of automation. The titration speed and dosage are automatically controlled by the computer, the sample injection, analysis, and result calculation are fully automated, the results are automatically calculated, and the electrode parameters are automatically calibrated to reduce human errors. The entire test process is truly unattended;

    8. Support fault self-diagnosis function, over-temperature protection function.

    9. The evaporation adjustment potentiometer adopts Taiwan TOCOS potentiometer, which has high linearity and long service life.

    10. Equipped with a high-precision digital ion meter to ensure the accuracy of the experiment.

    11. The evaporation capacity is adjusted digitally.

  • technical parameter

    Measuring range: fluorine 0.001%80%; chlorine 0.001%80%

    Analysis cycle: hydrolysis time chlorine (35 min/single sample), fluorine (35 min/single sample)

    Analysis time: chlorine (5 min/single sample), fluorine (5 min/single sample)

    High-temperature hydrolysis tube furnace: rated temperature 1300; hydrolysis temperature 1100±10; constant temperature zone length 100mm; temperature control accuracy ±3.

    Sample decomposition and collection: about 30min (no waterway cleaning required)

    Oxygen rotor flowmeter: measuring range 1000mL/min, minimum subscale 50mL/min;

    Water vapor evaporation: 2-3mL/min;

    Electric source: AC220V±10%; 50Hz; 5kW standard configuration

Соруrіght © Неbі Нuаnuо Еlесtrоnіс tесhnоlоgу со, LТD Аll Rіghtѕ Rеѕеrvеd.©